NS0-516 Exam Study Guide Free Practice Test LAST UPDATED DATE Jan 23, 2023
The New NS0-516 2023 Updated Verified Study Guides & Best Courses
NetApp NS0-516 Exam Certification Details:
| Exam Price | $150 USD |
| Sample Questions | NetApp NS0-516 Sample Questions |
| Duration | 90 minutes |
| Passing Score | 75% |
| Exam Code | NS0-516 NCIE SAN Specialist E-Series |
| Exam Name | Implementation Engineer SAN Specialist E-Series |
| Recommended Training | E-Series Fundamentals (WBT) Configuring and Monitoring NetApp E-Series and EF-Series Storage Systems (ILT) |
| Number of Questions | 60 |
NetApp NS0-516 Exam Topics:
| Section | Objectives |
|---|---|
| SAN | -Describe the end-to-end network configuration for Fibre Channel and Ethernet. |
| Host Side | -Describe the different host connection options for E-Series systems. -Describe how to configure hosts for multipathing. |
| Management | -Describe the administrative tasks for managing E-Series systems with SANtricity System Manager. -Describe the management security features in SANtricity System Manager and SANtricity Unified Manager. -Describe when and how to configure and use SANtricity Unified Manager. |
| Troubleshooting | -Demonstrate the steps for troubleshooting an E-Series system. -Demonstrate how to analyze multipathing issues between a host and an E-Series system. |
| Documentation | -Describe the process of reviewing and preparing a site for implementation of E-Series. -Describe the information you give a customer after deploying a solution. |
NEW QUESTION 37
Exhibit:
Referring to the exhibit, which three steps would you take to solve the problem shown in the event log? (Choose three.)
- A. Reinitialize the FC switch
- B. Swap out the FC cable
- C. Swap out the HBA on the FC switch
- D. Swap out the SFP in the controller port
- E. Move the connection to another controller port
Answer: A,B,D
NEW QUESTION 38
You are setting-up asynchronous mirroring between two E2860 systems.
In this scenario, which two prerequisites are required to complete the setup? (choose two)
- A. Both systems must be discovered by an Enterprise Management Window (EMW) or SANtricity Unified Manager
- B. both the primary and secondary systems must be using the same subnets for mirroring connections
- C. Both the primary and secondary systems must have the same premium features licensed
- D. The secondary system must have 2X the storage capacity of the primary system
Answer: A,C
NEW QUESTION 39
What mechanism governs control of the E-Series storage premium features? (Choose the best answer.)
- A. special USB flash drive that must be inserted into the controllers
- B. online database requiring the controllers to access the internet to activate features
- C. key file obtained from vendor and passed to system via SANtricity
- D. small toggle switches on the controller boards inside the system
- E. simple password system
Answer: C
NEW QUESTION 40
Which command collects detailed diagnostic information from a Brocade FC switch?
- A. diagshow
- B. showdiag
- C. showsupport
- D. supportshow
Answer: D
NEW QUESTION 41
Synchronous mirroring requires what type of connection between storage systems? (Choose the best answer.)
- A. FC
- B. SAS
- C. iSCSI
- D. InfiniBand
Answer: A
NEW QUESTION 42
A company is using the Federal Information Processing Standard (FIPS) on all volume groups. However, one volume group failed a security audit.
In this scenario what would cause a volume group to fail the security audit?
- A. The Secure Erase operation was applied to the volume group disks
- B. Data Assurance was changed to "disabled" for the volume group
- C. Connectivity to the key server was interrupted
- D. An FDE drive was added as a spare in the volume group
Answer: D
NEW QUESTION 43
You need to run a command from the SANtricity System Manager GUI to mark drives as native by using the CLI tool on an E-Series system that is running System Manager 11.60 or higher.
In this scenario, where would you locate this tool?
- A. Modify Existing Storage
- B. Help -> CLI Command Reference
- C. Settings -> System -> Addons
- D. Support -> Support Center -> Diagnostics
Answer: C
NEW QUESTION 44
When a drive fails in a Dynamic Disk Pool (DDP) with no free capacity, what happens to the data?
- A. It is evacuated to a hot spare drive that is assigned to the DD
- B. It is rebuilt using the on-board backup database
- C. It is evacuated to the preservation capacity within the DD
- D. It is rebuilt using preservation capacity within the DD
Answer: D
NEW QUESTION 45
You are cabling drive expansion shelves for an E2800 storage system.
In this scenario, which cabling method should you use?
- A. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should not be divided between the A-side and B-side IOM-12 modules for all of the expansion shelves.
- B. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should be divided between the A-side and B-side IOM-12 modules for all the expansion shelves.
- C. You use SAS expansion port EXP2 and reserve SAS expansion port EXP1 for a second drive expansion stack.
- D. You use SAS expansion port EXP1 and reserve SAS expansion port EXP2 for a second drive expansion stack.
Answer: B
Explanation:
Explanation
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2773537
NEW QUESTION 46
Your company has an E-Series system connected to Cisco MDS switches. You are asked to provision a volume on a new Windows host, but the Windows host is unable to connect to the volume on the E-Series system. All other Windows hosts in the fabric are able to connect to their volumes.
In this scenario, which three actions should you perform to accomplish this task? (Choose three.)
- A. Add a zone to the active zoneset
- B. Obtain the WWPN for the Windows HBA
- C. Create a single-initiator zone with the host and E-Series system
- D. Restart the switches
- E. Create a new virtual SAN (VSAN)
Answer: A,B,D
NEW QUESTION 47
What is the proper order to power-on E-Series arrays when a storage system has at least 2 trays? (Choose the best answer.)
- A. Power on the controller drive tray first, then wait several minutes for the controller drive tray to spin up, and then power on all expansion drive trays
- B. Power all expansion drive trays first, wait several minutes for the expansion drive trays to spin up, and then power on the controller drive tray
- C. Power on in any order, since the order does not matter
- D. Power up A-side power supplies first, then power up all B-side power supplies.
Answer: A
NEW QUESTION 48
A customer has launched a data analytics initiative and has been transferring old data into the new data lake.
The customer has discovered some data read errors during the transfer process.
In this scenario, how should the customer have avoided these data integrity issues?
- A. by deploying secure-capable drives
- B. by turning on cyclic redundancy checks (CRCs)
- C. by ensuring that data assurance and media scan are always activated
- D. by turning on erasure coding
Answer: C
NEW QUESTION 49
Click the Exhibit button.
An administrator is asked to create a 5532 GiB volume from the volume group.
Referring to the exhibit, how would the administrator complete this request?
- A. Create the volume from the available capacity
- B. Create the volume after adjusting the preservation capacity
- C. Create the volume after consolidating the capacity
- D. Create the volume after performing space reclamation
Answer: C
NEW QUESTION 50
What is the SANtricity Client? (Choose the best answer.)
- A. A GUI or CLI run on a host server used for storage system management
- B. Inter-process communication that supports computer program subordinates
- C. An OS-dependent collection of utilities for servers attached to SANtricity-managed storage systems
- D. A host I/O performance modeling interface
- E. A host server process that enables storage system management with the storage data path
Answer: C
NEW QUESTION 51
A d-stripe within a disk pool is always the equivalent of _______. (Choose the best answer.)
- A. 8+2 RAID 6
- B. 9+1 RAID 3
- C. 9+1 RAID 5
- D. 10+0 RAID 0
- E. 5+5 RAID 10
Answer: A
NEW QUESTION 52
The ability of many E-Series controllers to hold an additional firmware image in reserve _________. (Choose the best answer.)
- A. allows two firmware images to be used at the same time
- B. allows controller firmware to be downloaded immediately and activated at a later time
- C. is used for Support use only
- D. is used to store a backup boot image
Answer: A
NEW QUESTION 53
When you arrive on a customer site, you discover that the customer network administrator has called in sick. While required power has been provided and all of the components ordered have been physically accounted for, the network will not be operational today.
Which would be the most useful tool to complete your rack & stack and initial configuration of the system? (Choose the best answer.)
- A. None of the above, come back tomorrow.
- B. a CD containing the 10.86 version of SANtricity
- C. a standalone switch or hub
- D. a Serial Port cable
Answer: B
NEW QUESTION 54
What is the maximum number of FC host interface cards used per NetApp EF600 storage array?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 55
A company has just installed a NetApp EF600 storage array with an initial drive count of 12. A disk pool is created using all 12 disks. Benchmark testing now shows that system performance is far less than expected. Metrics show a very unbalanced use of the two PcIe busses and drives.
In this scenario, which action addresses this problem?
- A. Build two equally sized pools during disk pool creation.
- B. Insert six drives into the first 12 slots and six drives into the last 12 slots.
- C. Dynamically convert the volumes from RAID 10 to RAID 5.
- D. Adjust cache block sizes to 8k.
Answer: B